<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-16 12-40-09
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.40 MHz 4/5, 69 dBuV SelectUK
Pilot RDS Phase Difference
5.7 kHz 3.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 63 kHz 3764 0,4251
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,5 dBr 4,66 dBr 5,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SelectUK" C46F 15 (Other M) 1 0 1 5 12:39, 16.01.2026
RT
" "
AF EON
94.4, 99.3, 105.7 MHz -
FM Scope Max at: 63 kHz MIN: 8 kHz % above 76 kHz: 0,4251 Acquired: 2026/01/16 12.39.04 Total samples: 3764 Equivalent time: 0:03:08 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150 200
FM Scope MAX: 5,6 dBr MIN: 3,5 dBr AVE: 4,66 dBr % above 12,2 dBr: 0,0 Last value: 5,2 dBr (2026/01/16 12.39.03) 12.26 12.28 12.30 12.32 12.34 12.36 12.38 0 2 4 6 Pm [dBr]